Sensor Filter - NPN, PNP - Relay - None

Filter
  1. CLS-2L

    Condensed Clear Label Sensor, Cabled, NPN/PNP 12-30Vdc polarity protected.

  2. CLS-2LC

    Condensed Clear Label Sensor, 4-pin M12 connector, NPN/PNP 12-30Vdc polarity protected.

  3. CLS-2LM8

    Condensed Clear Label Sensor, 4-pin M8 connector, NPN/PNP 12-30Vdc polarity protected.

  4. MLELC

    MINI LABEL-EYE® with IR LED, and 4-Pin M8 Connector. NPN/PNP 35 microsecond response time. 4.75 to 30Vdc supply, polarity protected.

  5. MDIO4-10

    DC MITY•EYE® with Infrared LED and O4 Wide beam Proximity Block. 10ft 4-wire cable. 10 to 30 VDC, reverse polarity protected. Maximum sensing range 2 inches.

  6. TILR5

    TINY•EYE Infrared Light Source. Light-On Output. 10 to 30 VDC Supply Voltage. R5 Retroreflective Block. Maximum sensing range 20 feet.

  7. TRLV5

    TINY•EYE Red Light Source. Light-On Output. 10 to 30 VDC Supply Voltage. V5 Convergent 2" "V" Axis Block. Maximum sensing range is 1 inch.

  8. TRL5V5

    TINY•EYE Red Light Source. Light-On Output. 5 VDC Supply Voltage. V5 Convergent 2" "V" Axis Block. Maximum sensing range is 1 inch.

  9. TRDV5

    TINY•EYE Red Light Source. Dark-On Output. 10 to 30 VDC Supply Voltage. V5 Convergent 2" "V" Axis Block. Maximum sensing range is 1 inch.

  10. TRD5V5

    TINY•EYE Red Light Source. Dark-On Output. 5 VDC Supply Voltage. V5 Convergent 2" "V" Axis Block. Maximum sensing range is 1 inch.

  11. TILV5

    TINY•EYE Infrared Light Source. Light-On Output. 10 to 30 VDC Supply Voltage. V5 Convergent 2" "V" Axis Block. Maximum sensing range is 1 inch.

  12. TIL5V5

    TINY•EYE Infrared Light Source. Light-On Output. 5 VDC Supply Voltage. V5 Convergent 2" "V" Axis Block. Maximum sensing range is 1 inch.

  13. TIDV5

    TINY•EYE Infrared Light Source. Dark-On Output. 10 to 30 VDC Supply Voltage. V5 Convergent 2" "V" Axis Block. Maximum sensing range is 1 inch.

  14. PZICV5

    EZ-EYE™, Infrared, 4-wire M8 Connector, V5 Convergent 2" "V" Axis Block. 10 to 24 VDC Supply Voltage, polarity protected. Maximum sensing range is 1 inch.

  15. ORV5

    OPTI-EYE®, Red, 6ft 4-wire cable and V5 Convergent 2" "V" Axis Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 1 inch.

  16. ORCV5

    OPTI-EYE®, Red, 4-wire M12 Connector and V5 Convergent 2" "V" Axis Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 1 inch.

  17. MDRV5

    DC MITY•EYE® with Red LED and V5 Convergent 2" "V" Axis Block. 6ft 4-wire cable. 10 to 30 VDC, reverse polarity protected. Maximum sensing range 1 inch.

  18. MDRCV5

    DC MITY•EYE® with Red LED and V5 Convergent 2" "V" Axis Block. 4-wire M12 Connector. 10 to 30 VDC, reverse polarity protected. Maximum sensing range 1 inch.

  19. MDIV5

    DC MITY•EYE® with Infrared LED and V5 Convergent 2" "V" Axis Block. 6ft 4-wire cable. 10 to 30 VDC, reverse polarity protected. Maximum sensing range 1 inch.

  20. MDICV5

    DC MITY•EYE® with Infrared LED and V5 Convergent 2" "V" Axis Block. 4-wire M12 Connector. 10 to 30 VDC, reverse polarity protected. Maximum sensing range 1 inch.

  21. MDHRCV5

    DC MITY•EYE® with High Intensity Red LED and V5 Convergent 2" "V" Axis Block. 4-wire M12 Connector. 10 to 30 VDC, reverse polarity protected. Maximum sensing range 1 inch.

  22. MDHRV5

    DC MITY•EYE® with High Intensity Red LED and V5 Convergent 2" "V" Axis Block. 6ft 4-wire cable. 10 to 30 VDC, reverse polarity protected. Maximum sensing range 1 inch.

  23. SEIX86F1

    SMARTYEYE® MARK II with Infrared LED, potentiometer adjustment, 4-wire M12 Connector and F1 Fiberoptic Optical Block. 10 to 24 VDC Supply Voltage, polarity protected. The maximum range depends on fiberoptic.

  24. CMS-2BF1

    COLORMARK™ II, No Pulse Stretcher, Green LED, F1 Optical Block. 12-24 VDC polarity protected. Fiberoptic. Maximum Sensing Range is depending on fiber optics.

  25. CMS-2BTF1

    COLORMARK™ II, LT/DK Toggle Switch Green LED, F1 Optical Block. 12-24 VDC polarity protected. Fiberoptic. Maximum Sensing Range is depending on fiber optics.

  26. CMS-2BTV1G

    COLORMARK™ II, LT/DK Toggle Switch Green LED, V1G Optical Block. 12-24 VDC polarity protected. Convergent. Maximum Sensing Range is 2in (50.8mm).

  27. CMS-2BV1G

    COLORMARK™ II, No Pulse Stretcher, Green LED, V1G Optical Block. 12-24 VDC polarity protected. Convergent. Maximum Sensing Range is 2in (50.8mm).

  28. CMSB-2BF1

    COLORMARK™ II, No Pulse Stretcher, Blue LED, F1 Optical Block. 12-24 VDC polarity protected. Fiberoptic. Maximum Sensing Range is depending on fiber optics.

  29. CMSB-2BTF1

    COLORMARK™ II, LT/DK Toggle Switch Blue LED, F1 Optical Block. 12-24 VDC polarity protected. Fiberoptic. Maximum Sensing Range is depending on fiber optics.

  30. CMSB-2BTV1G

    COLORMARK™ II, LT/DK Toggle Switch Blue LED, V1G Optical Block. 12-24 VDC polarity protected. Convergent. Maximum Sensing Range is 2in (50.8mm).