Sensor Filter - PRO - MS - OPTI-EYE - PFS - Convergent - Fiberoptic - Displacement - Proximity

Filter
  1. MS-100A

    Long-Range Laser Distance Sensor
    Engineered for long-range precision, this sensor delivers accurate measurements over extended distances. Intuitive setup ensures fast deployment, while robust construction handles harsh conditions. Ideal for applications demanding reliable, high-performance sensing at greater ranges.

  2. MS-50A

    Mid-Range Laser Distance Sensor
    Provides precise and reliable distance measurements for mid-range applications. Designed for versatility and accuracy, it features simple setup with user-friendly controls and supports flexible output configurations. Built to perform in challenging industrial environments with ease.

  3. SPBIX97F4

    SMARTYEYE® PRO™, Infrared LED, 25ft cable with special 6-in connector, F4 Glass Fiberoptics Block. 10 to 30 VDC Supply Voltage, polarity protected. Maximum sensing range depends on the fiberoptic. Pulse Stretcher/OFF Delay Timer.

  4. ORV5

    OPTI-EYE®, Red, 6ft 4-wire cable and V5 Convergent 2" "V" Axis Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 1 inch.

  5. ORCV5

    OPTI-EYE®, Red, 4-wire M12 Connector and V5 Convergent 2" "V" Axis Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 1 inch.

  6. PFSRN

    PFS Sensor, Red, NPN, 6ft cable (1.8m).

  7. PFSRP

    PFS Sensor, Red, PNP, 6ft cable (1.8m).

  8. PFSRPC

    PFS Sensor, Red, PNP, M8 3-Pin Connector

  9. PFSRNC

    PFS Sensor, Red, NPN, M8 3-Pin Connector

  10. OICF4

    OPTI-EYE®, Infrared, 4-wire M12 Connector and F4 Glass Fiberoptics Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range depends on fiberoptic.

  11. OICO4

    OPTI-EYE®, Infrared, 4-wire M12 Connector and O4 wide beam Proximity Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 5 inches.

  12. OICO5

    OPTI-EYE®, Infrared, 4-wire M12 Connector and O5 narrow beam Proximity Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 3 feet.

  13. OICV4

    OPTI-EYE®, Infrared, 4-wire M12 Connector and V4 Convergent 1" "V" Axis Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 1 inch.

  14. OICV4A

    OPTI-EYE®, Infrared, 4-wire M12 Connector and V4A Apertured Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 1 inch.

  15. OICV6

    OPTI-EYE®, Infrared, 4-wire M12 Connector and V6 Convergent 1.5" "V" Axis Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 1.5 inches.

  16. OICV8

    OPTI-EYE®, Infrared, 4-wire M12 Connector and V8 Convergent 0.5" "V" Axis Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 0.5 inches.

  17. OIF4

    OPTI-EYE®, Infrared, 6ft 4-wire cable and F4 Glass Fiberoptics Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range depends on fiberoptic.

  18. OIO4

    OPTI-EYE®, Infrared, 6ft 4-wire cable and O4 wide beam Proximity Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 5 inches.

  19. OIO5

    OPTI-EYE®, Infrared, 6ft 4-wire cable and O5 narrow beam Proximity Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 3 feet.

  20. OIV4

    OPTI-EYE®, Infrared, 6ft 4-wire cable and V4 Convergent 1" "V" Axis Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 1 inch.

  21. OIV4A

    OPTI-EYE®, Infrared, 6ft 4-wire cable and V4A Apertured Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 1 inch.

  22. OIV6

    OPTI-EYE®, Infrared, 6ft 4-wire cable and V6 Convergent 1.5" "V" Axis Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 1.5 inches.

  23. OIV8

    OPTI-EYE®, Infrared, 6ft 4-wire cable and V8 Convergent 0.5" "V" Axis Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 0.5 inches.

  24. ORCF4

    OPTI-EYE®, Red, 4-wire M12 Connector and F4 Glass Fiberoptics Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range depends on fiberoptic.

  25. ORCF5

    OPTI-EYE®, Red, 4-wire M12 Connector and F5 Plastic Fiberoptics Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range depends on fiberoptic.

  26. ORCO4

    OPTI-EYE®, Red, 4-wire M12 Connector and O4 wide beam Proximity Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 2.5 inches.

  27. ORCO5

    OPTI-EYE®, Red, 4-wire M12 Connector and O5 narrow beam Proximity Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 1.5 feet.

  28. ORCV4

    OPTI-EYE®, Red, 4-wire M12 Connector and V4 Convergent 1" "V" Axis Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 1 inch.

  29. ORCV4A

    OPTI-EYE®, Red, 4-wire M12 Connector and V4A Apertured Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 1 inch.

  30. ORCV6

    OPTI-EYE®, Red, 4-wire M12 Connector and V6 Convergent 1.5" "V" Axis Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 1.5 inches.

Filter
Set Descending Direction

101 items

Page
per page