Sensor Filter - Relay - NPN, PNP - Potentiometer - Knob

Filter
  1. MDIO4-10

    DC MITY•EYE® with Infrared LED and O4 Wide beam Proximity Block. 10ft 4-wire cable. 10 to 30 VDC, reverse polarity protected. Maximum sensing range 2 inches.

  2. ORV5

    OPTI-EYE®, Red, 6ft 4-wire cable and V5 Convergent 2" "V" Axis Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 1 inch.

  3. ORCV5

    OPTI-EYE®, Red, 4-wire M12 Connector and V5 Convergent 2" "V" Axis Block. 12 to 24 VDC Supply Voltage, Polarity protected. Maximum sensing range is 1 inch.

  4. MDRV5

    DC MITY•EYE® with Red LED and V5 Convergent 2" "V" Axis Block. 6ft 4-wire cable. 10 to 30 VDC, reverse polarity protected. Maximum sensing range 1 inch.

  5. MDRCV5

    DC MITY•EYE® with Red LED and V5 Convergent 2" "V" Axis Block. 4-wire M12 Connector. 10 to 30 VDC, reverse polarity protected. Maximum sensing range 1 inch.

  6. MDIV5

    DC MITY•EYE® with Infrared LED and V5 Convergent 2" "V" Axis Block. 6ft 4-wire cable. 10 to 30 VDC, reverse polarity protected. Maximum sensing range 1 inch.

  7. MDICV5

    DC MITY•EYE® with Infrared LED and V5 Convergent 2" "V" Axis Block. 4-wire M12 Connector. 10 to 30 VDC, reverse polarity protected. Maximum sensing range 1 inch.

  8. MDHRCV5

    DC MITY•EYE® with High Intensity Red LED and V5 Convergent 2" "V" Axis Block. 4-wire M12 Connector. 10 to 30 VDC, reverse polarity protected. Maximum sensing range 1 inch.

  9. MDHRV5

    DC MITY•EYE® with High Intensity Red LED and V5 Convergent 2" "V" Axis Block. 6ft 4-wire cable. 10 to 30 VDC, reverse polarity protected. Maximum sensing range 1 inch.

  10. SEIX86F1

    SMARTYEYE® MARK II with Infrared LED, potentiometer adjustment, 4-wire M12 Connector and F1 Fiberoptic Optical Block. 10 to 24 VDC Supply Voltage, polarity protected. The maximum range depends on fiberoptic.

  11. CMS-1BF1

    COLORMARK™ II, 10ms Pulse Stretcher, Green LED, F1 Optical Block. 12-24 VDC polarity protected. Fiberoptic. Maximum Sensing Range is depending on fiber optics.

  12. CMS-1BV1G

    COLORMARK™ II, 10ms Pulse Stretcher, Green LED, V1G Optical Block. 12-24 VDC polarity protected. Convergent. Maximum Sensing Range is 2in (50.8mm).

  13. CMS-2BF1

    COLORMARK™ II, No Pulse Stretcher, Green LED, F1 Optical Block. 12-24 VDC polarity protected. Fiberoptic. Maximum Sensing Range is depending on fiber optics.

  14. CMS-2BTF1

    COLORMARK™ II, LT/DK Toggle Switch Green LED, F1 Optical Block. 12-24 VDC polarity protected. Fiberoptic. Maximum Sensing Range is depending on fiber optics.

  15. CMS-2BTV1G

    COLORMARK™ II, LT/DK Toggle Switch Green LED, V1G Optical Block. 12-24 VDC polarity protected. Convergent. Maximum Sensing Range is 2in (50.8mm).

  16. CMS-2BV1G

    COLORMARK™ II, No Pulse Stretcher, Green LED, V1G Optical Block. 12-24 VDC polarity protected. Convergent. Maximum Sensing Range is 2in (50.8mm).

  17. CMSB-1BF1

    COLORMARK™ II, 10ms Pulse Stretcher, Blue LED, F1 Optical Block. 12-24 VDC polarity protected. Fiberoptic. Maximum Sensing Range is depending on fiber optics.

  18. CMSB-1BV1G

    COLORMARK™ II, 10ms Pulse Stretcher, Blue LED, V1G Optical Block. 12-24 VDC polarity protected. Convergent. Maximum Sensing Range is 2in (50.8mm).

  19. CMSB-2BF1

    COLORMARK™ II, No Pulse Stretcher, Blue LED, F1 Optical Block. 12-24 VDC polarity protected. Fiberoptic. Maximum Sensing Range is depending on fiber optics.

  20. CMSB-2BTF1

    COLORMARK™ II, LT/DK Toggle Switch Blue LED, F1 Optical Block. 12-24 VDC polarity protected. Fiberoptic. Maximum Sensing Range is depending on fiber optics.

  21. CMSB-2BTV1G

    COLORMARK™ II, LT/DK Toggle Switch Blue LED, V1G Optical Block. 12-24 VDC polarity protected. Convergent. Maximum Sensing Range is 2in (50.8mm).

  22. CMSB-2BV1G

    COLORMARK™ II, No Pulse Stretcher, Blue LED, V1G Optical Block. 12-24 VDC polarity protected. Convergent. Maximum Sensing Range is 2in (50.8mm).

  23. CMSR-1BF1

    COLORMARK™ II, 10ms Pulse Stretcher, Red LED, F1 Optical Block. 12-24 VDC polarity protected. Fiberoptic. Maximum Sensing Range is depending on fiber optics.

  24. CMSR-1BV1G

    COLORMARK™ II, 10ms Pulse Stretcher, Red LED, V1G Optical Block. 12-24 VDC polarity protected. Convergent. Maximum Sensing Range is 2in (50.8mm).

  25. CMSR-2BF1

    COLORMARK™ II, No Pulse Stretcher, Red LED, F1 Optical Block. 12-24 VDC polarity protected. Fiberoptic. Maximum Sensing Range is depending on fiber optics.

  26. CMSR-2BTF1

    COLORMARK™ II, LT/DK Toggle Switch Red LED, F1 Optical Block. 12-24 VDC polarity protected. Fiberoptic. Maximum Sensing Range is depending on fiber optics.

  27. CMSR-2BTV1G

    COLORMARK™ II, LT/DK Toggle Switch Red LED, V1G Optical Block. 12-24 VDC polarity protected. Convergent. Maximum Sensing Range is 2in (50.8mm).

  28. CMSR-2BV1G

    COLORMARK™ II, No Pulse Stretcher, Red LED, V1G Optical Block. 12-24 VDC polarity protected. Convergent. Maximum Sensing Range is 2in (50.8mm).

  29. CMSWL-1BF1

    COLORMARK™ II, 10ms Pulse Stretcher, White LED, F1 Optical Block. 12-24 VDC polarity protected. Fiberoptic. Maximum Sensing Range is depending on fiber optics.

  30. CMSWL-1BV1G

    COLORMARK™ II, 10ms Pulse Stretcher, White LED, V1G Optical Block. 12-24 VDC polarity protected. Convergent. Maximum Sensing Range is 2in (50.8mm).

Filter
Set Descending Direction

338 items

Page
per page